A subcontractor agreement is a legal document between a primary contractor and a subcontractor, outlining the terms and conditions under which the subcontractor will perform specific tasks as part of a larger project.
SUBCONTRACTOR CHECKLIST
Project: | ||
Client Name: ________________________________ | LOCATION: _______________________________ | |
Contractor:_________________________________________________________________________ | ||
Subcontractor:______________________________________________________________________ | ||
Date Start: __________________________________ | Target Date of Accomplishment:_______________________________ | |
ARCHITECTURAL:
- HOUSE CONSTRUCTION (LIVABLE AND USABLE AREAS
- LANDSCAPING
- FENCE AND GATE
- OTHERS (PLEASE SPECIFY):__________________________________________________________________________________________________________________________________________________________________________________________________________________________
GROUND FLOOR
AREA(s) | FINISHES AND INCLUSIONS | TOTAL SQM (Measured wall to wall) |
GROUND FLOOR | ||
LIVING AREA | Flooring -Use 60 x 60 cm Vitrified Tiles (Color/ Design refer to swatch(s) given. -Use Tile adhesive -Use tile grout Ceiling: Cove layout ( see working drawings for details) Use gypsum board ______ mm THK. Use metal furring for framing. Use skim coat for finishing Use flat white paint. Walls: @ Exterior Walls Use 6’’ CHB plastered finish Use skim coat Use flat white latex paint primer Use semi-gloss paint for finishing Rebars: Specified @ drawings. Electrical: Roughing-in based on schedule and lay-out based on electrical plans,load computation and schedule shown @ drawings. Use Royu brand switches and convenience outlet (No. Will be based on drawings, BOM and BOQ given.) -Include panel Board. | |
DINING AREA | Flooring: -Use 60 x 60 cm Vitrified Tiles (Color/ Design refer to swatch(s) given). -Use Tile adhesive -Use tile grout Walls: @ Exterior Walls -Use 6’’ CHB plastered finish -Use skim coat -Use flat white latex paint primer -Use semi-gloss paint for finishing -Rebars: Specified @ drawings. @Interior Walls -Use 6 mm HardieFlex or approved as equal drywall -Use skim coat -Use flat white latex paint primer -Use semi-gloss paint for finishing -Use studs and tracks (see drawings for details) Note: Except toilet and bath(s) and Powder Room(s). Ceiling: Layout please based on working drawings -Use gypsum board ______ mm THK. -Use metal furring for framing. -Use skim coat for finishing -Use flat white paint. Electrical: Roughing-in based on schedule and lay-out based on electrical plans,load computation and schedule shown @ drawings. | |
KITCHEN AREA | FLOORING: -Use 60 x 60 cm Vitrified Tiles/Non- Slip Tiles (Color/ Design refer to swatch(s) given. -Use Tile adhesive -Use tile grout Walls: @ Exterior Walls -Use 6’’ CHB plastered finish -Use skim coat -Use flat white latex paint primer -Use semi-gloss paint for finishing -Rebars: Specified @ drawings. @Interior Walls -Use 6 mm HardieFlex or approved as equal drywall -Use skim coat -Use flat white latex paint primer -Use semi-gloss paint for finishing -Use studs and tracks (see drawings for details) Note: Except toilet and bath(s) and Powder Room(s). Ceiling: Flat Ceiling -Use gypsum board ______ mm THK. -Use metal furring for framing. -Use skim coat for finishing -Use flat white paint. Electrical: Roughing-in based on schedule and lay-out based on electrical plans, load computation and schedule shown @ drawings. Use Royu brand switches and convenience outlet. (No. Will be based on drawings, BOM and BOQ given.) Include panel Board. Plumbing: –Use specified sanitary pipes and fittings @ BOM, BOQ and Working Drawings. –Use specified waterline pipes and fittings @ BOM, BOQ and Working Drawings. Inclusions: –1.80 li. mts. Cabinets -Use ¾ “ Marine Plywood – Use Laminate Finish (Color/ Design refer to swatch(s) given). -1.80 li. mts. Hanging Cabinets -Use ¾ “ Marine Plywood – Use Laminate Finish (Color/ Design refer to swatch(s) given). -Fixture Inclusion 1-sink (Single-Tub w/ Drain) 1-Single lever kitchen faucet (gooseneck) | |
POWDER ROOM/ T&B | Flooring: Use 30 cm x 30 cm non-slip tiles (Color/ Design refer to swatch(s) given.) -Use Tile adhesive -Use tile grout Walls: -Use 4’’ CHB wall -Use 30 cm x 60 cm glazed tiles (Color/ Design refer to swatch(s) given.)for Finishing -Use tile adhesive -Use tile Grout Ceiling: Flat Ceiling -Use 3.5 mm THK HardieFlex or approved as equal plaster board. -Use metal furring for framing. -Use skim coat for finishing -Use flat white paint. Electrical: Roughing-in based on schedule and lay-out based on electrical plans, load computation and schedule Shown @ drawings. Use Royu brand switches and convenience outlet. (No. Will be based on drawings, BOM and BOQ given.) Include panel Board. Plumbing: –Use specified sanitary pipes and fittings @ BOM, BOQ and Working Drawings. –Use specified waterline pipes and fittings @ BOM, BOQ and Working Drawings. Inclusions: (Cool or Pozzi Brand or Approved as equal) Fixtures: Wall hang lavatory Water Closet Bidet Spray Faucet ( Single handle basin mixer faucet) as indicated number(s) Telephone Shower (if included @ draings) Appurtenances: Soap and Tissue Holder Fittings | |
SERVICE AREA | Flooring: Concrete Pavement @ Counter top 60 cm X 60 cm tiles @Depressed at sink area PLUMBING: -Hose bibb and roughing-in | |
PORCH | Concrete pavement | |
LANAI | Concrete pavement | |
CARPORT | Flooring: Concrete Pavement PLUMBING: -Hose bibb and roughing-in | |
MAID’S ROOM | Flooring: – HDF Wood Laminate 194 x 1212 x 8mm (color/design as per approved swatch of client) -Use –Use adhesive based on installation process required. Walls: @ Exterior Walls -Use 6’’ CHB plastered finish -Use skim coat -Use flat white latex paint primer -Use semi-gloss paint for finishing -Rebars: Specified @ drawings. @Interior Walls -Use 6 mm HardieFlex or approved as equal drywall -Use skim coat -Use flat white latex paint primer -Use semi-gloss paint for finishing -Use studs and tracks (see drawings for details) Note: Except toilet and bath(s) and Powder Room(s). Ceiling: Layout please based on working drawings -Use gypsum board ______ mm THK. -Use metal furring for framing. -Use skim coat for finishing. -Use flat white paint. Electrical: Roughing-in based on schedule and lay-out based on electrical plans,load computation and schedule shown @ drawings. | |
MASTER BEDROOM | Flooring: – HDF Wood Laminate 194 x 1212 x 8mm (color/design as per approved swatch of client) -Use –Use adhesive based on installation process required. Walls: @ Exterior Walls -Use 6’’ CHB plastered finish -Use skim coat -Use flat white latex paint primer -Use semi-gloss paint for finishing -Rebars: Specified @ drawings. @Interior Walls -Use 6 mm HardieFlex or approved as equal drywall -Use skim coat -Use flat white latex paint primer -Use semi-gloss paint for finishing -Use studs and tracks (see drawings for details) Note: Except toilet and bath(s) and Powder Room(s). Ceiling: Layout please based on working drawings -Use gypsum board ______ mm THK. -Use metal furring for framing. -Use skim coat for finishing. -Use flat white paint. Electrical: Roughing-in based on schedule and lay-out based on electrical plans, load computation and schedule shown @ drawings. | |
MASTER WALK IN CLOSET | Flooring: – HDF Wood Laminate 194 x 1212 x 8mm (color/design as per approved swatch of client) -Use –Use adhesive based on installation process required. Walls: @ Exterior Walls -Use 6’’ CHB plastered finish -Use skim coat -Use flat white latex paint primer -Use semi-gloss paint for finishing -Rebars: Specified @ drawings. @Interior Walls -Use 6 mm HardieFlex or approved as equal drywall -Use skim coat -Use flat white latex paint primer -Use semi-gloss paint for finishing -Use studs and tracks (see drawings for details) Note: Except toilet and bath(s) and Powder Room(s). Ceiling: Layout please based on working drawings -Use gypsum board ______ mm THK. -Use metal furring for framing. -Use skim coat for finishing. -Use flat white paint. Electrical: Roughing-in based on schedule and lay-out based on electrical plans,load computation and schedule shown @ drawings. INCLUSIONS: 1.2 MTS WIDTH CABINET -Use ¾” Marine Plywood -Use Laminate for finish ( Color /Design as approved swatch) | |
MASTER T&B | Flooring: Use 30 cm x 30 cm non-slip tiles (Color/ Design refer to swatch(s) given.) -Use Tile adhesive -Use tile grout -Use waterproofing Walls: -Use 4’’ CHB wall -Use 30 cm x 60 cm glazed tiles (Color/ Design refer to swatch(s) given.)for Finishing -Use tile adhesive -Use tile Grout Ceiling: Flat Ceiling -Use 3.5 mm THK HardieFlex or approved as equal plaster board. -Use metal furring for framing. -Use skim coat for finishing -Use flat white paint. Electrical: Roughing-in based on schedule and lay-out based on electrical plans,load computation and schedule Shown @ drawings. Use Royu brand switches and convenience outlet. (No. Will be based on drawings, BOM and BOQ given.) Include panel Board. Plumbing: –Use specified sanitary pipes and fittings @ BOM, BOQ and Working Drawings. –Use specified waterline pipes and fittings @ BOM, BOQ and Working Drawings. Inclusions: (Cool or Pozzi Brand or Approved as equal) Fixtures: Pedestal type lavatory Water Closet Bidet Spray Faucet ( Single handle basin mixer faucet) Telephone Shower Appurtenances: Soap and Tissue Holder Fittings | |
__ BEDROOM (S) | Flooring: – HDF Wood Laminate 194 x 1212 x 8mm (color/design as per approved swatch of client) -Use –Use adhesive based on installation process required. Walls: @ Exterior Walls -Use 6’’ CHB plastered finish -Use skim coat -Use flat white latex paint primer -Use semi-gloss paint for finishing -Rebars: Specified @ drawings. @Interior Walls -Use 6 mm HardieFlex or approved as equal drywall -Use skim coat -Use flat white latex paint primer -Use semi-gloss paint for finishing -Use studs and tracks (see drawings for details) Note: Except toilet and bath(s) and Powder Room(s). Ceiling: Flat Ceiling -Use gypsum board ______ mm THK. -Use metal furring for framing. -Use skim coat for finishing. -Use flat white paint. Electrical: Roughing-in based on schedule and lay-out based on electrical plans, load computation and schedule shown @ drawings. INCLUSIONS: 0.80 MTS WIDTH CABINET -Use ¾” Marine Plywood -Use Laminate for finish ( Color /Design as approved swatch) | |
COMMON T&B | Flooring: Use 30 cm x 30 cm non-slip tiles (Color/ Design refer to swatch(s) given.) -Use Tile adhesive -Use waterproofing -Use tile grout Walls: -Use 4’’ CHB wall -Use 30 cm x 60 cm glazed tiles (Color/ Design refer to swatch(s) given.)for Finishing -Use tile adhesive -Use tile Grout Ceiling: Flat Ceiling -Use 3.5 mm THK HardieFlex or approved as equal plaster board. -Use metal furring for framing. -Use skim coat for finishing -Use flat white paint. Electrical: Roughing-in based on schedule and lay-out based on electrical plans,load computation and schedule Shown @ drawings. Use Royu brand switches and convenience outlet. (No. Will be based on drawings, BOM and BOQ given.) Include panel Board. Plumbing: –Use specified sanitary pipes and fittings @ BOM, BOQ and Working Drawings. –Use specified waterline pipes and fittings @ BOM, BOQ and Working Drawings. Inclusions: (Cool or Pozzi Brand or Approved as equal) Fixtures: Pedestal type lavatory Water Closet Bidet Spray Faucet ( Single handle basin mixer faucet) Telephone Shower Appurtenances: Soap and Tissue Holder Fittings | |
BALCONY | FLOORING: -Use plain concrete pavement -Use waterproofing RAILING -Use 2” x 2” tubular painted. | |
ROOFING | -Use gauge 24 pre-painted long span roofing. -Use reflective bubble insulation. | |
WINDOWS | -Use 6mm THK. Anneal glass (or shaded) in Aluminum Frame Powder Coated – Note: In larger span of glass 6 mm Tempered Glass must to use. | |
STAIRS | -Concrete Stairs -Use Wood Planks on stair treads. -Use 2”X2” tubular railing or s specified to drawings. -Use Wooden millwork on handrail top | |
EXTERIOR FINISHING | As shown in drawings Note: This may include claddings, wood and tiles. | |
EAVES | -Use 3.5mm THK HARDIEFLEX OR APPROVED AS EQUAL PLASTER BOARD. -Use plain White Paint/ Wood Stain if specified. | |
DOORS | -As reflected to the Schedule of doors and windows. | |
NOTES: |
Construction of _____________________________________________________________________
(Project Nature)
At ________________________________________________________________________________
(Location)
SUB-CONTRACTOR AGREEMENT
THIS AGREEMENT is made ___________________between _________________________________
(Date)
____________________________________________________ (Hereafter, called “CONTRACTOR”),
(Company Name and Address- Main Contractor)
and_______________________________________________________________________________
(Company Name and Address- Sub-Contractor)
(Hereafter, called “THE SUB-CONTRACTOR”), of the mentioned part above.
In consideration of payment to be made by the Contractor to the Sub-Contractor, the Sub-Contractor hereby covenants with the Contractor to execute, complete and maintain the Sub-Contract works in conformity in all respects with the terms and conditions of this Agreement.
In WITNESS thereof the Contractor and the Sub-Contractor have hereunto set their respective hands the day and the year first above written.
Authorized Signatory
On Behalf of the Sub-Contractor
____________________________
Authorized Signatory
On Behalf of the Contractor
____________________________
Printed Name and Signature Printed Name and Signature